Citia Micro-Webinar

MOV not read in SCADA? Practical troubleshooting from gateway to field device

Citia Micro-Webinar #03, Friday 21 November 2026 at 14.00 WIB on Microsoft Teams: a free 20-minute case study on MOVs that SCADA cannot read.

Date
21 November 2026
Time
14.00 WIB
Speakers
Rofiqi Hidayat (Control System Engineer, PT Citia Engineering Indonesia)
Status
Announced
Topics
4

Get session reminders by email

We send new session announcements, then the poster and the join link the day before or on the day.

Email me about webinars

The button works once the page has finished loading.

Or RSVP on WhatsApp with siTia.

What the session covers

Topics

What the session covers

  1. 01

    MOV case study: some devices read, some do not

  2. 02

    Communication architecture: MOV, RS-485, gateway, SCADA

  3. 03

    Troubleshooting steps: power, wiring, address, polling, command and feedback

  4. 04

    Lessons learned and a diagnosis checklist

Overview

A motor-operated valve (MOV) is a valve driven by an electric actuator, so the control room can open, close and stop it without sending someone to the pipe rack. The actuator also reports back: valve position, open or closed status, local or remote mode, thermal condition, torque and faults.

That feedback reaches SCADA over a serial line, usually RS-485, through a gateway that polls each actuator by address. When only part of a group of MOVs appears in SCADA, the devices that do answer already prove that SCADA and part of the path are alive. The work is to find where the silent ones drop out.

Micro-Webinar #03 takes that case and works along the path from the gateway to the field device. It is a short session, about 20 minutes, built around one field problem and the checklist that came out of it.

For background before the session, Citia's MOV communication project at a fuel terminal in Jambi describes a path of the same shape, and the guides on Modbus RS-485 troubleshooting, Modbus and SCADA explain the protocol and the system around it.

  • 21 Nov 2026DateFriday
  • 14.00 WIBTimeAbout 20 minutes
  • TeamsPlatformOnline via Microsoft Teams
  • FreeFeeRSVP through siTia
The communication path the session follows
Field
Control
Application
MOV actuator

Reports position, open/close, local/remote, thermal, torque and fault.

Hover, focus or tap a step to read its note.
The troubleshooting order

The troubleshooting order

  1. Power

    Confirm the actuator and its communication electronics have supply before looking further.

  2. Wiring

    Follow the RS-485 pair from the gateway to the silent device: terminals, polarity and continuity.

  3. Address

    Each MOV on the line needs a unique address that matches the gateway configuration.

  4. Polling

    Check that the gateway actually polls the device with the right register, function code, baud rate and parity.

  5. Command and feedback

    Send a command from SCADA and read the MOV feedback back on SCADA to close the loop.

Who will find it useful

Engineers and technicians who maintain MOVs, RS-485 lines, gateways or SCADA at terminals and plants, and supervisors who need to know where a "not read" alarm comes from.

Speaker: Rofiqi Hidayat, Control System Engineer, PT Citia Engineering Indonesia.

Series
Micro-Webinar #03
Platform
Microsoft Teams
Fee
Free
RSVP
siTia on WhatsApp, reply HADIR

Dates

  1. 13 Nov 2026

    Session announced

    RSVP opens through siTia on WhatsApp.

  2. 21 Nov 2026, 14.00 WIB

    Live on Microsoft Teams

    About 20 minutes.

  3. After the session

    Page updated

    This page will state whether material or a recording is published.

Common questions

When is the MOV SCADA troubleshooting webinar?

Friday 21 November 2026 at 14.00 WIB, online through Microsoft Teams, for about 20 minutes.

Is Citia Micro-Webinar #03 free, and how do I register?

Yes, it is free. Reply HADIR to siTia on WhatsApp at +62 813-2206-507, or use the email reminder button on this page.

Why would some MOVs show in SCADA while others do not?

Because the fault sits somewhere between the gateway and the silent devices, not in SCADA as a whole. The session checks power, wiring, address, polling, and command and feedback to find the point where those devices drop out.

What communication path does the session cover?

MOV to RS-485 to gateway to SCADA. In Citia's Jambi MOV project the same path adds a surge protection device on the RS-485 side and a LAN arrester between the gateway and SCADA.

Will there be a recording?

Citia has not announced one. After the session this page will say whether material or a recording is available.

Next step

Register for this session.

Registration opens on the organiser's page.