This project restores normal operation of the distribution pumps and VSD by separating the control system. The system was first centralized on one Allen-Bradley (AB) PLC.

| Field | Value |
| --- | --- |
| Year | 2022 |
| Status | Finished |
| Work types | Instrumentation, HMI, SCADA, Motor, VFD |
| Updated | 2026-08-24 |

## About this work

**Overview** This project restores normal operation of the distribution pump and VSD system so it works properly. Before, all field logic was controlled centrally by an Allen-Bradley (AB) PLC. To improve performance and operational focus, the team modified the system by separating a dedicated control panel for distribution/pumps and VSD from the main system.

**Challenges**

- **Migrating a live system:** Separate the pump and VSD control logic from the existing central (AB) PLC program without disturbing other functions that remain on that PLC.
- **Multi-vendor integration:** Make sure the existing AB PLC, the new Siemens S7-1200 PLC and the Vijeo Citect v7 SCADA communicate and stay in sync.

**Solutions**

- **Added a dedicated panel:** Installed a new PLC panel with a Siemens S7-1200, dedicated to the distribution system workload (pumps & VSD).
- **Reprogramming across platforms:** Modified the AB PLC program to release the pump functions, and wrote new control logic on the Siemens 1200 PLC.
- **SCADA update:** Reconfigured the *tags*, communication and HMI graphics in the Vijeo Citect v7 SCADA so operators can control this decentralized architecture smoothly.

**Lessons learned** Decentralizing the control of critical systems (such as pumps and VSD) into separate panels (*dedicated controller*) proved very effective for restoring the system. It reduces the processing load on the main PLC and makes *troubleshooting* and *maintenance* much easier later. Devices from different *brands* (AB and Siemens) can work well together if the network design and the SCADA configuration are done correctly.

## Contact

- Company: PT Citia Engineering Indonesia
- Email: services@citiaengineering.com
- Telephone: +62 21 278 20286
- Office: Jl. Kaimun Jaya No. 1, Cilandak Barat, Jakarta Selatan, DKI Jakarta 12430, Indonesia

[Contact Citia](https://citia-engineering.com/en/contact.md)

## Structured data (JSON-LD)

```json
{
  "@context": "https://schema.org",
  "@graph": [
    {
      "@type": "Organization",
      "@id": "https://citia-engineering.com/#organization",
      "name": "Citia Engineering Indonesia",
      "legalName": "PT Citia Engineering Indonesia",
      "alternateName": "Citia",
      "url": "https://citia-engineering.com",
      "logo": {
        "@type": "ImageObject",
        "url": "https://citia-engineering.com/media/citia-logo.png",
        "width": 950,
        "height": 328
      },
      "description": "Citia is an engineering and system integration company in Jakarta. We connect field devices, PLC and SCADA, terminal software and enterprise systems, then install, test and maintain them.",
      "email": "services@citiaengineering.com",
      "telephone": "+62 21 278 20286",
      "address": {
        "@type": "PostalAddress",
        "streetAddress": "Jl. Kaimun Jaya No. 1, Cilandak Barat",
        "addressLocality": "Jakarta Selatan",
        "addressRegion": "DKI Jakarta",
        "postalCode": "12430",
        "addressCountry": "ID"
      },
      "contactPoint": {
        "@type": "ContactPoint",
        "contactType": "customer service",
        "email": "services@citiaengineering.com",
        "telephone": "+62 21 278 20286",
        "url": "https://citia-engineering.com/en/contact"
      },
      "areaServed": {
        "@type": "Country",
        "name": "Indonesia"
      },
      "knowsAbout": [
        "Terminal automation & operations",
        "Tank farm & inventory",
        "Control systems & instrumentation",
        "Reliability & lifecycle",
        "Industrial IoT & monitoring",
        "Installation & site engineering",
        "INTEGRA: Software that runs terminal operations",
        "CATALYST: Devices and gateways that collect field data",
        "Services: Engineering that designs, installs, integrates and maintains both"
      ]
    },
    {
      "@type": "WebSite",
      "@id": "https://citia-engineering.com/#website",
      "url": "https://citia-engineering.com",
      "name": "Citia Engineering Indonesia",
      "inLanguage": [
        "en",
        "id"
      ],
      "publisher": {
        "@id": "https://citia-engineering.com/#organization"
      },
      "potentialAction": [
        {
          "@type": "SearchAction",
          "name": "Search Citia News",
          "target": {
            "@type": "EntryPoint",
            "urlTemplate": "https://citia-engineering.com/en/news?q={search_term_string}"
          },
          "query-input": "required name=search_term_string"
        },
        {
          "@type": "SearchAction",
          "name": "Cari di News Citia",
          "target": {
            "@type": "EntryPoint",
            "urlTemplate": "https://citia-engineering.com/id/news?q={search_term_string}"
          },
          "query-input": "required name=search_term_string"
        }
      ]
    },
    {
      "@type": "WebPage",
      "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#webpage",
      "url": "https://citia-engineering.com/en/projects/vsd-system-optimization",
      "name": "VSD system optimization",
      "description": "This project restores normal operation of the distribution pumps and VSD by separating the control system. The system was first centralized on one…",
      "inLanguage": "en",
      "isPartOf": {
        "@id": "https://citia-engineering.com/#website"
      },
      "publisher": {
        "@id": "https://citia-engineering.com/#organization"
      },
      "about": {
        "@id": "https://citia-engineering.com/#organization"
      },
      "breadcrumb": {
        "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#breadcrumb"
      },
      "dateModified": "2026-08-24",
      "mainEntity": {
        "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#entity"
      }
    },
    {
      "@type": "BreadcrumbList",
      "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#breadcrumb",
      "itemListElement": [
        {
          "@type": "ListItem",
          "position": 1,
          "name": "Citia",
          "item": "https://citia-engineering.com/en"
        },
        {
          "@type": "ListItem",
          "position": 2,
          "name": "Projects",
          "item": "https://citia-engineering.com/en/projects"
        },
        {
          "@type": "ListItem",
          "position": 3,
          "name": "VSD system optimization",
          "item": "https://citia-engineering.com/en/projects/vsd-system-optimization"
        }
      ]
    },
    {
      "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#entity",
      "url": "https://citia-engineering.com/en/projects/vsd-system-optimization",
      "mainEntityOfPage": {
        "@id": "https://citia-engineering.com/en/projects/vsd-system-optimization#webpage"
      },
      "@type": "Article",
      "headline": "VSD system optimization",
      "description": "This project restores normal operation of the distribution pumps and VSD by separating the control system. The system was first centralized on one Allen-Bradley (AB) PLC.",
      "dateModified": "2026-08-24",
      "author": {
        "@id": "https://citia-engineering.com/#organization"
      },
      "publisher": {
        "@id": "https://citia-engineering.com/#organization"
      },
      "inLanguage": "en",
      "about": [
        {
          "@type": "Thing",
          "name": "Instrumentation"
        },
        {
          "@type": "Thing",
          "name": "HMI"
        },
        {
          "@type": "Thing",
          "name": "SCADA"
        },
        {
          "@type": "Thing",
          "name": "Motor"
        },
        {
          "@type": "Thing",
          "name": "VFD"
        }
      ]
    }
  ]
}
```